1 / 5
| Model | MAXMAX II 8000 | MAXMAX II 11000 |
|---|---|---|
| Rated Power | 8000VA/8000W | 11000VA/11000W |
| Parallel Capability | Yes, up to 6 units | |
| INPUT | ||
| Voltage | 230 VAC | |
| Selectable Voltage Range | 170-280VAC (PC); 90-280VAC (Home Appliances) | |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | |
| OUTPUT | ||
| AC Voltage Regulation | 230 VAC ± 5% | |
| Surge Power | 16000VA | 22000VA |
| Efficiency (Peak) | 93% | |
| Waveform | Pure sine wave | |
| SOLAR & AC CHARGER | ||
| Solar Charger Type | MPPT | |
| Max PV Array Power | 8000W (4000Wx2) | 11000W (5500Wx2) |
| MPP Range @ Operating Voltage | 90-450VDC | |
| Max Charge Current | 150A | |